کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6253157 1612297 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original scientific articleIntensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVP
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
پیش نمایش صفحه اول مقاله
Original scientific articleIntensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVP
چکیده انگلیسی

BackgroundVolume status assessment is an important aspect of patient management in the surgical intensive care unit (SICU). Echocardiologist-performed measurement of IVC collapsibility index (IVC-CI) provides useful information about filling pressures, but is limited by its portability, cost, and availability. Intensivist-performed bedside ultrasonography (INBU) examinations have the potential to overcome these impediments. We used INBU to evaluate hemodynamic status of SICU patients, focusing on correlations between IVC-CI and CVP.Study DesignProspective evaluation of hemodynamic status was conducted on a convenience sample of SICU patients with a brief (3 to 10 minutes) INBU examination. INBU examinations were performed by noncardiologists after 3 hours of didactics in interpreting and acquiring two-dimensional and M-mode images, and ≥25 proctored examinations. IVC-CI measurements were compared with invasive CVP values.ResultsOf 124 enrolled patients, 101 had CVP catheters (55 men, mean age 58.3 years, 44.6% intubated). Of these, 18 patients had uninterpretable INBU examinations, leaving 83 patients with both CVP monitoring devices and INBU IVC evaluations. Patients in three IVC-CI ranges (<0.20, 0.20 to 0.60, and >0.60) demonstrated significant decrease in mean CVP as IVC-CI increased (p = 0.023). Although <5% of patients with IVC-CI <0.20 had CVP <7 mmHg, >40% of this group had a CVP >12 mmHg. Conversely, >60% of patients with IVC-CI >0.6 had CVP <7 mmHg.ConclusionsMeasurements of IVC-CI by INBU can provide a useful guide to noninvasive volume status assessment in SICU patients. IVC-CI appears to correlate best with CVP in the setting of low (<0.20) and high (>0.60) collapsibility ranges. Additional studies are needed to confirm and expand on findings of this study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Surgeons - Volume 209, Issue 1, July 2009, Pages 55-61
نویسندگان
, , , , , , , , ,