کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
625540 1455429 2010 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Energy audit of a full scale MBR system
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Energy audit of a full scale MBR system
چکیده انگلیسی

A calibrated dynamic biological ASM model of a full scale membrane bioreactor (MBR) was used to analyze the energy costs of different compartments and devices. The overall energy consumption (0.64 kWh/m3 of permeate) of the studied MBR in Schilde (Belgium) was good compared to other full scale municipal MBR plants. It is however still much higher than conventional activated sludge (CAS) treatment (0.3 kWh/m3). Energy demands of the full scale MBR system were compared with a treatment train believed to deliver a comparable effluent quality: CAS followed by Ultrafiltration and UV. It was concluded that from an energy perspective the MBR technology is not yet sufficiently competitive.The MBR technology leads to process specificities which all impact on the energy consumption. While the higher MLSS concentrations implied significant mixing energy costs and reduced oxygen transfer, the smaller floc size did not reflect in a significant aeration energy saving. The impact of the filtration process on the overall energy consumption could be reduced if the coarse aeration flow would be better integrated in the biological process scheme of submerged MBRs. However this work indicates a minimal contribution of the coarse aeration flow to the biological oxygen requirements.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Desalination - Volume 262, Issues 1–3, 15 November 2010, Pages 121–128