کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
626927 1455456 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Boiler feed water deoxygenation using hollow fiber membrane contactor
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Boiler feed water deoxygenation using hollow fiber membrane contactor
چکیده انگلیسی

A pilot plant scale hollow fiber membrane system was developed for the removal of dissolved oxygen from boiler feed water via vacuum degassing process. Feed water was introduced to the shell side; a vacuum was applied to the lumen side of the hollow fiber. The effects of water flow rate, vacuum level, and water temperature on removal efficiency of dissolved oxygen and mass transfer coefficient were investigated. The membrane fouling issue was further addressed on the membrane used on the full-scale system. The foulants were identified by SEM, ATR/FTIR, EDX and water analysis to be the organic matter with the combination of aluminum silicate. Mass transfer resistances of the fouled membrane were also theoretically calcualted. Finally, two membrane cleaning methods were investigated and the air backwash method was found to be effective to clean the fouled membrane and was recommended as the regular cleaning method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Desalination - Volume 234, Issues 1–3, 31 December 2008, Pages 370-377