کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
628290 1455483 2007 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Steady-state experimental studies on a multi-effect thermal regeneration solar desalination unit with horizontal tube falling film evaporation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Steady-state experimental studies on a multi-effect thermal regeneration solar desalination unit with horizontal tube falling film evaporation
چکیده انگلیسی

A special desalinization unit which utilizes solar or waste energy has been developed and tested indoors. In thisunit, a relatively large fraction of latent and sensible heat of condensation along with brine is successfully recycled and utilized. It is used to preheat and evaporate the feedstock due to the multi-effect thermal regenerative process. Since the falling film evaporation is used and the system posses the characteristics of flash distillation and vapor compression, the thermal performance of the system is improved greatly. As a result of the simulation of the unitoperating with a solar system under practical weather conditions, the yield is about two times greater than that of a conventional single basin solar still with the same thermal energy input. The transient-state performance of the unit, the relationships among the operating temperature, feedstock flow rate and the productivity are presented. Other factors which influence the freshwater yield are also discussed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Desalination - Volume 207, Issues 1–3, 10 March 2007, Pages 59-70