کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6289396 1616330 2013 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimal temperature for microbes in an acetate fed microbial electrolysis cell (MEC)
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست علوم زیست محیطی (عمومی)
پیش نمایش صفحه اول مقاله
Optimal temperature for microbes in an acetate fed microbial electrolysis cell (MEC)
چکیده انگلیسی


- Optimum temperature for COD reduction in MEC batch reactor was 31 °C.
- Biomass concentration decreased in MECs but rate of reduction was less at 30 and 31 °C.
- Biomass concentration and temperature significantly affected the reactor performance.

Temperature is one of the important parameters which can significantly effect on the activity/selection of microorganism and subsequently on the reactor's performance. Two microbial electrolysis cells (MECs) were operated at different temperature settings with acetate as a carbon source. On average, COD removal rates of 16.8, 24.7, 34.0, 36.2 and 18.1 mg/l/h were recorded at 25, 29, 30, 31 and 35 °C, respectively. The results of volatile suspended solids analysis indicated that biomass concentration continued to drop at all temperatures, but the drop was the lowest at 30 °C. Consideration of biomass drop and specific COD removal rate showed 31 °C as the optimum temperature. These significant results imply that effect of temperature and change in biomass concentration should be considered in future experiments when expressing the removal rates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Biodeterioration & Biodegradation - Volume 85, November 2013, Pages 688-692
نویسندگان
, ,