کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6462535 1421980 2017 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Statistical comparison of mass spectra for identification of amphetamine-type stimulants
ترجمه فارسی عنوان
مقایسه آماری طیف جرمی برای شناسایی محرک های نوع آمفتامین
کلمات کلیدی
شناسایی مواد کنترل شده، مقایسه طیفی توده، طیف سنجی جرم کروماتوگرافی گاز، محرک های نوع آمفتامین،
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


- Unequal variance t-test used to compare two mass spectra at every m/z value.
- Amphetamine-type stimulants associated to reference standard at 99.9% confidence level.
- Distinction from other reference standards at 99.9% and 99.0% confidence level.
- Random-match probability (RMP) calculated for statistically equivalent spectra.
- Number of discriminating ions determined for statistically distinct spectra.

A method for the statistical comparison of mass spectral data is demonstrated for applications in controlled substance analysis. The method uses an unequal variance t-test at each mass-to-charge ratio in the scan range to determine if two spectra are statistically associated or discriminated. If the two spectra are associated, a random-match probability is calculated to estimate the likelihood that the mass spectral fragmentation pattern in question occurs by random chance alone. If the two spectra are discriminated, the fragment ions responsible for the discrimination are determined.In this work, mass spectral data from case samples containing amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), phentermine, and psilocin were investigated. All spectra were collected in an accredited forensic laboratory using routine methods for controlled substance analysis. Using the statistical method, spectra of case samples were statistically associated to the corresponding reference standard at the 99.9% confidence level. In these instances, random-match probabilities ranged from 10−39 to 10−29, indicating the probability that the characteristic fragmentation pattern occurred by random chance is extremely small. Further, spectra of case samples were discriminated from other reference standards at the 99.9% or 99.0% confidence level, with 1-26 ions responsible for discrimination in each comparison.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Forensic Science International - Volume 270, January 2017, Pages 111-120