کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6480791 1428772 2017 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Structural performance of FCS wall subjected to axial load
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Structural performance of FCS wall subjected to axial load
چکیده انگلیسی


- The ultimate load, load-deflection profile and strain distribution of FCS wall subjected to axial load are obtained.
- The effects of various slenderness ratio of FCS walls strengthened with DSC on its structural behavior are obtained.
- The ultimate shear load of FCS walls under push off load test is obtained.
- FCS walls with DSC attained higher ultimate load and composite action compared to walls with SSC.
- FCS wall strengthened with DSC is found to behave in a partially composite manner.

The primary purpose of this paper is to present the structural behavior of precast foamed concrete sandwich walls (FCS) strengthened with double steel shear connectors (DSC) subjected to axial load. The discussion of results addresses the effect of slenderness ratio (H/t) on the behavior of the walls. It also addresses the significant effects of using double shear connectors on these behaviors compared to single steel shear connector (SSC). The FCS wall was modeled using ABAQUS and validated by the results from experiment and previous research. Parametric finite element study (FEA) was conducted by simulating these walls with various H/t under axial load. The structural behavior recorded from FEA includes its ultimate load, failure mode, load-deflection profiles, strain distribution across the wall's thickness, and ultimate shear load. It was found that as H/t increased, the ultimate load decreased but the maximum horizontal deflection increased. FCS with H/t ⩽25 failed from crushes and cracks within the top and bottom area while FCS with H/t ⩾25 failed from buckling at its mid-height. It was also noticed that FCS with lower H/t experienced more uniform strain distribution across its thickness. FCS with DSC was able to sustain higher load but it deflected less compared to walls with SSC, caused by higher stiffness due to larger steel areas. It is interesting to find that FCS walls with DSC behaved in a more composite manner and was able to sustain higher ultimate shear force under push of loading test compared to FCS walls with SSC. These findings show that the FCS wall with DSC is suitable to be used as a load-bearing wall.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Construction and Building Materials - Volume 134, 1 March 2017, Pages 185-198
نویسندگان
, , , , , ,