کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
652050 884999 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of unsteadiness in effervescent sprays by analysis of droplet arrival statistics - The influence of fluids properties and atomizer internal design
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Evaluation of unsteadiness in effervescent sprays by analysis of droplet arrival statistics - The influence of fluids properties and atomizer internal design
چکیده انگلیسی
A short mixing chamber results in less unsteady for water but has no effect on spray unsteadiness for high-viscosity or non-Newtonian fluids at ALR of 0.15. Otherwise, the influence of mixing chamber distance on the spray quality is weak at ALR of 0.15. Large diameter of inclined aeration holes shows the low spray unsteadiness and good spray quality for water but causes more unsteady for glycerol/water/xanthan mixture at ALR of 0.15. Furthermore, the diameter of the inclined aeration holes has little influence on spray unsteadiness for glycerol/water mixture. Spray unsteadiness and quality are not affected by the angle of aeration holes for three fluids at ALR of 0.15.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 35, Issue 1, January 2011, Pages 190-198
نویسندگان
, , , ,