An experimental study on the effect of the valve angle of counter-flow Ranque–Hilsch vortex tubes on thermal energy separation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
An experimental study on the effect of the valve angle of counter-flow Ranque–Hilsch vortex tubes on thermal energy separation
چکیده انگلیسی

An experimental study is conducted to investigate effects of the conical valve angle on thermal energy separation in a counter-flow vortex tube. A new geometry is designed for the cold end side, which is called ‘helical swirl flow generator’. Combined and interactive effects of the helical length of the swirl flow generator, the ratio of the tube length to the tube inner diameter (L/D), the inlet pressure and especially the angle of the conical valve on the performance of the vortex tube are comparatively investigated as a function of the cold mass fraction, yc. Four different conical valves have been used with the angle of 30°, 45°, 60° and 75°. Finally, it is observed that the effect of the valve angle on the performance changes according to the value of L/D and, it has a weak influence on the system performance.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 34, Issue 7, October 2010, Pages 966–971