کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
653554 | 1457508 | 2013 | 9 صفحه PDF | دانلود رایگان |
This work deals with the experimental investigation on Nusselt number, friction factor and thermal performance factor in a circular tube equipped with perforated twisted tape inserts with four different porosities of Rp = 1.6, 4.5, 8.9 and 14.7%. The experiments were conducted in a turbulent flow regime with Reynolds number ranging from 7200 to 49,800 using air as the working fluid under uniform wall heat flux boundary condition. The experimental results revealed that both heat transfer rate and friction factor of the tube fitted with perforated twisted tapes were significantly higher than those of the plain tube. Over the range investigated, Nusselt number, friction factor and thermal performance factor in the tube with perforated twisted tape inserts was found to be 110 –340, 110 –360 and 28–59% higher than those of the plain tube values, respectively. In addition, the empirical correlations of Nusselt number, friction factor and thermal performance factor were formulated from the experimental results of tape inserts.
Journal: International Communications in Heat and Mass Transfer - Volume 46, August 2013, Pages 49–57