کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
656088 1457653 2011 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-phase flow of refrigerants in 85 μm-wide multi-microchannels: Part I – Pressure drop
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Two-phase flow of refrigerants in 85 μm-wide multi-microchannels: Part I – Pressure drop
چکیده انگلیسی

This article is the first part of a study on flow boiling of R236fa and R245fa. This part presents pressure drop measurements obtained on a silicon multi-microchannel evaporator with 85 μm wide and 560 μm high channels separated by 46 μm wide fins. The 135 microchannels were 12.7 mm long. Dielectric refrigerants R236fa and R245fa were used as the evaporating test fluids. The inlet saturation temperature was maintained at 30.5 °C while the mass fluxes were varied from 499 to 1100 kg/m2 s and the base heat flux was tested from 130 to 1400 kW/m2. A new experimental technique was developed to measure the outlet pressure losses, which represented up to 30% of the total pressure drop and thus cannot be neglected. The microchannel pressure drop measurements were very well predicted by the method of Cioncolini et al. (2009).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Heat and Fluid Flow - Volume 32, Issue 2, April 2011, Pages 451–463
نویسندگان
, , , , ,