In order to improve product efficiency and reduce the manufacturing cost, the chloride ion (Clâ) selective electrode was prepared through immersing silver wire in the sodium hypochloride acid (SHA) solution. The performances, such as reversibility and responding time, sensitivity and limit of detection, long-term stability and reliability, of this electrode were investigated in simulating concrete pore solutions as well as concrete. Results revealed that the electrode potential exhibited good Nernst response to Clâ content. Besides, the detection limit at pH 13.5 and lower pH values was ca. 10â3 and 10â4 mol Lâ1, respectively. The electrode coating indicated well stability over an immersion period of three months in solutions with Clâ. Furthermore, the electrode was capable to provide reliable and sustained real-time information by which the total Clâ content could be calculated. Therefore, the Clâ selective electrode is a promising tool because the electrode fabricated by the SHA technique enables us to get low-cost, miniaturized and reliable long-term sensors for Clâ monitoring.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Construction and Building Materials - Volume 122, 30 September 2016, Pages 310-319
Journal: Construction and Building Materials - Volume 122, 30 September 2016, Pages 310-319
نویسندگان
Ming Jin, Linhua Jiang, Debiao Tao, Shuya Bai,