کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
673649 | 1459515 | 2013 | 7 صفحه PDF | دانلود رایگان |
• Gamma ray densitometer has been fabricated in our laboratory based on the ideas of the Drotning [1].
• Aluminum alloys have been prepared by ingot metallurgy route.
• Stronger change of density with increase in temperature has been observed in 2014 alloy.
• DSC studies indicate more microstructural change in 2014 alloy.
The temperature dependence of linear attenuation coefficient, density and thermal expansion of 6061, 2219 and 2014 aluminum alloys have been studied by gamma ray attenuation technique in the temperature range 298–773 K. The gamma ray attenuation studies have been carried out using a gamma ray densitometer fabricated in our laboratory. The linear attenuation coefficients (μl) for the alloys as a function of temperature and the coefficients of temperature dependence of density have been reported. The variation of density and thermal expansion of these alloys have been represented by linear equations. Volume thermal expansion coefficients have been reported.
Journal: Thermochimica Acta - Volume 569, 10 October 2013, Pages 90–96