کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
674437 1459560 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
X-ray diffraction study of multiphase reverse reaction with molten CuCl and oxygen
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
X-ray diffraction study of multiphase reverse reaction with molten CuCl and oxygen
چکیده انگلیسی

The thermochemical copper–chlorine (Cu–Cl) cycle for hydrogen production includes three chemical reactions of hydrolysis, decomposition and electrolysis. The decomposition of copper oxychloride for oxygen production establishes the high-temperature limit of the cycle. At 450–530 °C, copper oxychloride (Cu2OCl2) decomposes to produce a molten salt of cuprous chloride (CuCl, copper I chloride) and oxygen gas. Minimization of the reverse reaction and undesirable products is critical for the proper operation of the Cu–Cl cycle. This paper examines the operating conditions that disfavor the reverse reaction of the oxygen production, and the parameters that maximize the extent of the forward reaction. Experiments were designed to disperse oxygen gas into a molten CuCl bath to study its reaction at 450–500 °C. The composition of the products was quantified with X-ray diffraction measurements. Experimental results indicate that a high decomposition extent of copper oxychloride is obtained at equilibrium when the temperature is higher than 500 °C, and the oxygen pressure is below 2 bar. The thermochemistry data of the reactants and products were also determined and reported. These thermodynamic data provide a key missing gap in the understanding of the Cu–Cl cycle of thermochemical hydrogen production. The data includes the standard formation entropy, enthalpy and Gibbs free energy at different temperatures. Also, in this paper, a thermodynamic analysis is performed to investigate the reverse reaction from the aspects of spontaneity and optimization of the operating parameters. It is found that the optimal operating parameters for minimizing the reverse reaction lie in the pressure range of 1–2 bar and a temperature range of 500–525 °C.


► This paper examines the reverse reactions associated with copper oxychloride decomposition in the copper–chlorine cycle of hydrogen production.
► Experiments are designed to disperse oxygen gas into a molten CuCl bath to study its reaction at 450–500 °C and the composition of the products is quantified with X-ray diffraction measurements.
► It is found that the optimal operating parameters for minimizing the reverse reaction lie in the pressure range of 1–2 bar and a temperature range of 500–525 °C.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thermochimica Acta - Volume 524, Issues 1–2, 20 September 2011, Pages 109–116
نویسندگان
, , , ,