کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6762072 511725 2014 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Assessment of GOTHIC and TRACE codes against selected PANDA experiments on a Passive Containment Condenser
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Assessment of GOTHIC and TRACE codes against selected PANDA experiments on a Passive Containment Condenser
چکیده انگلیسی
In general, this study shows that both the GOTHIC and TRACE codes are able to reasonably predict the heat transfer capability of the PCC as well as the influence of non-condensable gas on the system. A slight underestimation of the condenser performance is obtained with both codes. For those tests where the experimental and simulated efficiencies agree better the possibility of compensating errors among different parts of the heat transfer models is outlined. Besides, the pool side heat transfer coefficient is indicated to differ between GOTHIC and TRACE, revealing that the model implemented in TRACE might be more accurate. Finally, both codes deviate more from the experiments for the tests with helium, which is explained by the emerging of a complex circulatory flow pattern in the experiments that the models fail to predict.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 278, 15 October 2014, Pages 542-557
نویسندگان
, , , ,