Study of reactor plant disturbed cooling condition modes caused by the VVER reactor secondary circuit
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
Based on the RELAP-5, TRAC, and TRACE software codes, reactor plant cooling condition malfunction modes caused by the VVER-1000 secondary circuit were simulated and investigated. Experimental data on the mode with the turbine-generator stop valve closing are presented. The obtained dependences made it possible to determine the maximum values of pressure and temperature in the circulation circuit as well as estimate the Minimum Critical Heat Flux Ratio (MCHFR). It has been found that, if any of the initial events occurs, safety systems are activated according to the set points; transient processes are stabilized in time; and the Critical Heat Flux (CHF) limit is provided. Therefore, in the event of emergency associated with the considered modes, the reactor plant safety will be ensured.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Energy and Technology - Volume 2, Issue 4, December 2016, Pages 256-261
Journal: Nuclear Energy and Technology - Volume 2, Issue 4, December 2016, Pages 256-261
نویسندگان
V.I. Belozerov, E.N. Botko, M.M. Zhuk,