This paper introduces a modified slip energy recovery drive system for speed control of a wound rotor induction motor offering improvement of drive performance, particularly line power factor and overall system efficiency. A 12-pulse line commutated thyristor converter operating in an inverter mode in conjunction with an additional IGBT shunt chopper is employed to transfer slip energy back to ac mains supply via three phase transformers. This approach offers motor speed control by varying the duty cycle of the chopper instead of changing the inverter firing angle. As a consequence, supply power factor can be improved. The servo state feedback designed by linear quadratic regulator (LQR) with observer is also included in order to keep motor speed to be constant over a certain range of operating conditions by using the estimated dc link current derived from motor speed. The advantage of this technique is absence of current transducers for current feedback control loop. The overall control system is implemented on DSP, DS1104’TMS320F240 controller board. Experimental results are illustrated in order to validate performance of the proposed system.
Journal: Electric Power Systems Research - Volume 78, Issue 5, May 2008, Pages 861–872