کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7051498 | 1457378 | 2018 | 18 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Investigating the influence of the configuration of the bundle of heat exchanging tubes and column size on the gas holdup distributions in bubble columns via gamma-ray computed tomography
ترجمه فارسی عنوان
بررسی تأثیر پیکربندی بسته نرم افزاری لوله های مبدل حرارتی و اندازه ستون بر توزیع های نگهدارنده گاز در ستون های حباب با استفاده از توموگرافی کامپوزیتی گاما
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
جریان سیال و فرایندهای انتقال
چکیده انگلیسی
The impact of dense vertical internal tubes and their configurations on the gas holdup distributions and their diametrical profiles in pilot-scale bubble column is visualized and quantified for the first time ever using an advanced gamma-ray computed tomography (CT) technique. Two arrangements of vertical internals (circular and hexagonal configurations) occupying the same cross-sectional area (CSA) of the column (about 25% of the total cross-sectional area to represent the heat exchanging tubes that are used in the Fischer-Tropsch synthesis), were examined in addition to the measurement in the bubble column without vertical internals. Moreover, the gas holdup distribution results of the 18-inch (0.46â¯m in outer diameter, O.D.) bubble column are compared with an available data of 6-inch (0.15â¯m in O.D.) bubble columns with and without vertical internals. CT scans have been conducted for 18-inch bubble columns with and without vertical internals for the air-water system under a wide range of superficial gas velocity (0.05-0.45â¯m/s). The experimental results indicate that an improvement in the gas holdup distribution over the column's cross-sectional area is obtained when the vertical internal tubes (arranged in either a circular or a hexagonal configuration) were used. However, better cross-sectional gas holdup distribution was achieved in the bubble column with vertical internals arranged in a hexagonal configuration as compared to the bubble column without and with vertical internals arranged in a circular arrangement. Additionally, the averages of the cross-sectional gas holdup and their profiles for bubble column with and without vertical internals are close to each other when the bubble column with vertical internals is operating at a high superficial gas velocity, which is calculated based on the free cross-sectional area for the flow. Furthermore, the gas holdup distributions are further improved when the larger bubble column with vertical internals was used as compared to the 6-inch bubble columns with and without vertical internals.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 98, November 2018, Pages 68-85
Journal: Experimental Thermal and Fluid Science - Volume 98, November 2018, Pages 68-85
نویسندگان
Abbas J. Sultan, Laith S. Sabri, Muthanna H. Al-Dahhan,