Experimental investigation of thermal performance of flat and v-corrugated plate solar air heaters with and without PCM as thermal energy storage
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی (عمومی)
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The thermal performance parameters were studied when the mass flow rates were 0.062, 0.028 and 0.009 kg/s. The effect of changing the thickness of PCM below the absorber plate was also studied. From the experimental results, it was found that when using the PCM, the outlet temperature of the v-corrugated plate solar air heater was higher than ambient temperature by 1.5-7.2 °C during 3.5 h after sunset compared with 1-5.5 °C during 2.5 h after sunset for flat plate solar air heater when the mass flow rate was 0.062 kg/s. It was also concluded that the daily efficiency of the v-corrugated solar heater using PCM was 12% higher than the corresponding ones without using the PCM and it was also 15% and 21.3% higher than the corresponding values when the flat plate was used with and without PCM when the mass flow rate was 0.062 kg/s, respectively.