کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7207020 | 1469061 | 2018 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی پزشکی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Time-elapsed micro-computed-tomography (μCT) imaging allows studying bone micromechanics. However, no study has yet performed time-elapsed μCT imaging of human femoral neck fractures. We developed a protocol for time-elapsed synchrotron μCT imaging of the microstructure in the entire proximal femur, while inducing clinically-relevant femoral neck fractures. Three human cadaver femora (females, age: 75-80 years) were used. The specimen-specific force to be applied at each load step was based on the specimens' strength estimated a priori using finite-element analysis of clinical CT images. A radio-transparent compressive stage was designed for loading the specimens while recording the applied load during synchrotron μCT scanning. The total μCT scanning field of view was 146â¯mm wide and 131â¯mm high, at 29.81â¯Âµm isotropic pixel size. Specimens were first scanned unloaded, then under incremental load steps, each equal to 25% of the estimated specimens' strength, and ultimately after fracture. Fracture occurred after 4-5â¯time-elapsed load steps, displaying sub-capital fracturing of the femoral neck, in agreement with finite-element predictions. Time-elapsed μCT images, co-registered to those of the intact specimen, displayed the proximal femur microstructure under progressive deformation up to fracture. The images showed (1) a spatially heterogeneous deformation localized in the proximal femoral head; (2) a predominantly elastic recovery, after load removal, of the diaphyseal and trochanteric regions and; (3) post-fracture residual displacements, mainly localized in the fractured region. The time-elapsed μCT imaging protocol developed and the high resolution images generated, made publicly available, may spur further research into human femur micromechanics and fracture.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 84, August 2018, Pages 265-272
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 84, August 2018, Pages 265-272
نویسندگان
Saulo Martelli, Egon Perilli,