کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
727830 892808 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improvement of primary power standard through international comparison feedback
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
Improvement of primary power standard through international comparison feedback
چکیده انگلیسی
The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effective efficiency measurement of power sensors both of bolometric and thermoelectric type. The critical point in the power standard realization is in the determination of the calibration constant g of the microcalorimeter, a frequency dependent parameter that has huge impact on the accuracy assessment of the standard. The paper proposes a simple but powerful way for improving this accuracy by using the reference values provided by international key-comparisons which the microcalorimeter was involved in.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 42, Issue 10, December 2009, Pages 1487-1490
نویسندگان
, , ,