کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
741794 894263 2007 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Novel surface plasmon resonance (SPR) immunosensor based on monomolecular layer of physically-adsorbed ovalbumin conjugate for detection of 2,4-dichlorophenoxyacetic acid and atomic force microscopy study
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Novel surface plasmon resonance (SPR) immunosensor based on monomolecular layer of physically-adsorbed ovalbumin conjugate for detection of 2,4-dichlorophenoxyacetic acid and atomic force microscopy study
چکیده انگلیسی

A rapid and simple optical immunosensor for detection of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) has been developed based on SPR technology. Functional sensing surface of the immunosensor is created by immobilizing an ovalbumin conjugate of 2,4-D (2,4-D-OVA) by simple physical adsorption on an SPR thin-film gold chip. It has been established that the Au surface of the sensor chip was completely covered by 2,4-D-OVA up to a monomolecular layer and that the 2,4-D-OVA immobilized sensor chip was highly resistive to non-specific binding of proteins. Selective binding of a monoclonal antibody against 2,4-D (2,4-D-Ab) is followed by an increase in SPR angle. The antibody complexed on the sensor surface could be removed simply by the flow of an acidic buffer (glycine.HCl; 0.2 M, pH 2.0) for less than 1 min, facilitating repeated use of a same sensor chip. A competitive immunosensing method has been applied for the detection of 2,4-D, in which binding of the antibody onto the sensor surface in the presence and absence of 2,4-D is investigated. When 2,4-D is present in sample solution, a competition is set off between 2,4-D in solution and 2,4-D-OVA conjugate on sensor chip for binding to 2,4-D-Ab. A lowest detection limit of 0.1 ng/ml 2,4-D is established. Calibration curve of this analytical system covers a wide concentration range of 0.1–300 ng/ml 2,4-D. One assay could be completed in 18 min (binding, 15 min; acidic eluent and followed carrier buffer, 3 min). Enzyme-linked immunosorbent assay (ELISA) measurements for the detection of 2,4-D using analogous antigen-coat format showed a detection limit of 500 ng/ml. The high sensitivity of the configured SPR immunosensor system and the differences between the performances of SPR and ELISA are discussed. Cross-reactivity of the SPR sensor against a few compounds structurally and environmentally relevant to 2,4-D is examined. The fabricated SPR sensor is found to be highly resistant to interference with a maximum cross-reactivity of only 4% for 2,4,5-trichlorophenoxyacetic acid (2,4,5-T).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 123, Issue 1, 10 April 2007, Pages 583–593
نویسندگان
, , , , ,