کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
751480 895233 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle
چکیده انگلیسی

Hemoglobin (Hb) was immobilized on one-dimensional (1D) gold (Au) nanoparticles to construct a novel amperometric biosensor for hydrogen peroxide (H2O2) and nitrite (NO2−). 1D Au nanoparticles were prepared by electrodepositon in the pores of an alumina template and were characterized by XRD and TEM. The immobilized Hb retained its biological activity well and displayed a good response to the reduction of both H2O2 and NO2−. Its apparent Michaelis–Menten constants for H2O2 and NO2− were 10.8 and 35.3 μM, respectively, showing a good affinity. Under optimal conditions, the biosensors could be used for the determination of H2O2 ranging from 0.6 to 12.4 μM and NO2− ranging from 0.4 to 14.8 μM. The detection limits were 2.4 × 10−8 and 6.5 × 10−8 M at 3σ, respectively. 1D Au nanoparticles provided a good matrix for protein immobilization and biosensor preparation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 140, Issue 1, 18 June 2009, Pages 222–226
نویسندگان
, ,