کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
760768 1462886 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring and energetic performance of two similar semi-closed greenhouse ventilation systems
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Monitoring and energetic performance of two similar semi-closed greenhouse ventilation systems
چکیده انگلیسی


• Measurements on two semi-closed greenhouses and two traditional open greenhouses.
• Mechanical and natural ventilation for dehumidification and cooling.
• Analyses and comparison of installation controls, indoor climate and energy flows.
• Examination of air-to-air heat recuperation efficiency in ventilation unit.
• Using the semi-closed systems amounted to energy savings of 13% and 28%.

Horticulture is an energy intensive industry when dealing with cold climates such as Western Europe. High energy prices and on-going pressure from international competition are raising demand for energy efficient solutions. In search of reducing greenhouse energy consumption, this study investigates semi-closed systems combining controlled mechanical and natural ventilation with thermal screens. Ventilated greenhouse systems (semi-closed) have been implemented in the greenhouse compartments of two Belgian horticulture research facilities: the Research Station for Vegetable Production Sint-Katelijne-Waver (PSKW) and the Research Center Hoogstraten (PCH). Additionally, two reference compartments were included for comparison of the results. The greenhouses were part of a long-term monitoring campaign in which detailed measurements with a high time resolution were gathered by a central monitoring system. A large amount of data was processed and analysed, including outdoor and indoor climatic parameters, system controls and installation measurements. The ventilated greenhouses obtained energy savings of 13% and 28% for PSKW and PCH respectively, without substantial impact on crop production or indoor climate conditions when compared to the reference compartments. A considerable amount of heat was recovered by the heat recuperation stage in the ventilation unit of PCH, accounting for 12% of the total heat demand. In general, it was demonstrated that the greenhouse heat demand can be reduced significantly by controlled dehumidification with mechanical ventilation, especially during spring and autumn.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Conversion and Management - Volume 76, December 2013, Pages 128–136
نویسندگان
, , , ,