کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
787193 1466446 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector
چکیده انگلیسی

The performance of the heat pump can be improved further when running under low temperature conditions when an ejector is used in a heat pump system coupled with economized vapor injection (EVI) scroll compressor. In this paper, the design method of the heat pump system with ejector (EVIe) is presented, and the process for designing the heat pump with ejector has been summarized. The optimal location of the vapor injection inlets is at the place where the vapor can inject into the working chambers when they just be closed. The reasonable value for the entrainment ratio u of the ejector is between 0.1 and 0.2. One prototype heat pump was designed under the condition of the evaporation temperature of −20 °C, and an experimental setup was established to test the prototype. The measured results demonstrated that the heating EER of the heat pump system with ejector could reach about 4% higher than that of the system without ejector when the heating capacity remained nearly constant.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Refrigeration - Volume 34, Issue 7, November 2011, Pages 1587–1595