کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8054893 | 1519496 | 2018 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A novel dielectric tensiometer enabling precision PID-based irrigation control of polytunnel-grown strawberries in coir
ترجمه فارسی عنوان
یک تنیسیمتر دی الکتریک جدید که امکان کنترل دقیق آب آبیاری از توت فرنگی های پلی توتون را در کوسه
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
کنترل و سیستم های مهندسی
چکیده انگلیسی
The benefits of closed-loop irrigation control have been demonstrated in grower trials which show the potential for improved crop yields and resource usage. Managing water use, by controlling irrigation in response to soil or substrate moisture changes, to meet crop water demands is a popular approach but requires substrate specific moisture sensor calibrations and knowledge of the moisture levels that result in water deficit or over-watering. The use of water tension sensors removes the need for substrate specific calibration and enables a more direct relationship with hydraulic conductivity. In this paper, we present a novel dielectric tensiometer that has been designed specifically for use in soil-free substrates such as coir, peat and Rockwool with a water tension measurement range of â0.7 kPa to â2.5 kPa. This new sensor design has also been integrated with a precision PID-based (drip) irrigation controller in a small-scale coir substrate strawberry growing trial: 32 strawberry plants in 4 coir growbags under a polytunnel. The data illustrates that excellent regulation of water tension in coir can be achieved which delivers robust and precise irrigation control - matching water delivery to the demands of the plants. During a 30-day growing period vapour pressure deficit (VPD) and daily water use data was collected and the irrigation controller set to maintain coir water tension at the following levels: â0.90 kPa, â0.95 kPa and â1 kPa for at least 7 consecutive days at each level. For each set-point the coir water tension was maintained by the irrigation controller to within ±0.05 kPa. Meanwhile the polytunnel VPD varied diurnally from 0 to a maximum of 5 kPa over the trial period. Furthermore, the combination of the dielectric tensiometer and the method of PID-based irrigation control resulted in a linear relationship between daily average VPD and daily water use over 10 days during the cropping period.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosystems Engineering - Volume 165, January 2018, Pages 70-76
Journal: Biosystems Engineering - Volume 165, January 2018, Pages 70-76
نویسندگان
Martin S. Goodchild, Malcolm D. Jenkins, William R. Whalley, Chris W. Watts,