کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8072211 1521403 2018 17 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Primary control reserve of electric power by feedwater flow rate change through an additional economizer - A case study of the thermal power plant “Nikola Tesla B”
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Primary control reserve of electric power by feedwater flow rate change through an additional economizer - A case study of the thermal power plant “Nikola Tesla B”
چکیده انگلیسی
In this paper a new method for the primary power control in TPPs is presented, based on the feedwater flow rate changes between the feedwater heaters (FWHs) and an additional high pressure economizer. The achieved primary power control reserve is demonstrated by measurements at the lignite-fired 650 MWe TPP after its retrofit by the installation of the high pressure economizer in parallel with FWHs. In addition, the TPP transient operation during the primary control are simulated and analyzed with the developed thermal-hydraulic model of the steam turbine heat regeneration system. The control reserve of approximately 10 MWe is shown both by measured data and results of numerical simulations. The control reserve is originally provided by the fresh steam throttling in front of the turbine, but this throttling can be reduced by the application of the new method. The rates of change of wall temperatures of FWHs tubes are within allowed limits during the transients.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy - Volume 147, 15 March 2018, Pages 782-798
نویسندگان
, , , , , ,