کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8098881 1522076 2018 17 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Flexible hybrid renewable energy system design for a typical remote village located in tropical climate
ترجمه فارسی عنوان
طراحی سیستم انرژی تجدید پذیر ترکیبی قابل انعطاف برای یک روستای راه دور معمولی که در آب و هوای گرمسیری قرار دارد
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
Energy management and sustainable resources are regarded as major concerns when designing hybrid energy systems. Finding an efficient framework that combines reliable design and satisfies continuous operation at minimal cost at all conditions is essential for both customers and investors. In this regard, this paper details the adoption of a creative approach using HOMER software to come up with a flexible design of a hybrid system that includes conventional and renewable energy sources. This study involves a comprehensive survey in this field, detailed techno-economic assessments, analyses of operational performance, and the evaluation of environmental aspects pertaining to the aforementioned system. It investigates all conditions that influence the system for both off-grid and on-grid connections by examining it over a typical remote Malaysian village. A sensitivity analysis was also conducted at all stages to verify the optimum design among all changes of different sell-back, power purchase, fuel prices, load growth, and other variables. Also, this study was proceeded to determine and examine the technical, economical and environmental aspects of the system. The results showed that the optimum system for both off-grid and on-grid connections consists of 300 kWp of photovoltaic (PV) modules, two diesel generators rated at 100 kW and 50 kW, a 150 kW converter and 330 kWh battery banks. The total Net Present Cost (NPC) and Cost of Energy (COE) fell within (1500000.0-2450000.0 $) and (0.151-0.233 $/kWh), respectively, for different renewable energy fraction (RF) values of (23-55.43%) and CO2 emissions of (245284.0-570643.0 kg/Yr). Moreover, the results indicated the importance of considering all parameters prior to the implementation of any hybrid system in order to realize the proposed objectives. The study demonstrates the high capability of the proposed flexible design in meeting the loads, support continuous operation, and reduce the harmful emissions towards the environment over all conditions for both off-grid and on-grid connections.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cleaner Production - Volume 177, 10 March 2018, Pages 908-924
نویسندگان
, ,