• Intervertebral disc model convergence and poromechanical calculations assessed.
• Material discontinuities led to numerical instabilities of fluid flow predictions.
• Increased shear stiffness in the annulus caused volumetric strain fluctuations.
• Creating an annulus–nucleus material transition zone reduced instabilities by 91%.
• Simulating the osmotic pressure further stabilized the poromechanical predictions.
Numerical studies of the intervertebral disc (IVD) are important to better understand the load transfer and the mechanobiological processes within the disc. Among the relevant calculations, fluid-related outputs are critical to describe and explore accurately the tissue properties. Porohyperelastic finite element models of IVD can describe accurately the disc behaviour at the organ level and allow the inclusion of fluid effects. However, results may be affected by numerical instabilities when fast load rates are applied. We hypothesized that such instabilities would appear preferentially at material discontinuities such as the annulus–nucleus boundary and should be considered when testing mesh convergence. A L4–L5 IVD model including the nucleus, annulus and cartilage endplates were tested under pure rotational loads, with different levels of mesh refinement. The effect of load relaxation and swelling were also studied. Simulations indicated that fluid velocity oscillations appeared due to numerical instability of the pore pressure spatial derivative at material discontinuities. Applying local refinement only was not enough to eliminate these oscillations. In fact, mesh refinements had to be local, material-dependent, and supplemented by the creation of a material transition zone, including interpolated material properties. Results also indicated that oscillations vanished along load relaxation, and faster attenuation occurred with the incorporation of the osmotic pressure. We concluded that material discontinuities are a major cause of instability for poromechanical calculations in multi-tissue models when load velocities are simulated. A strategy was presented to address these instabilities and recommendations on the use of IVD porohyperelastic models were given.
Figure optionsDownload high-quality image (231 K)Download as PowerPoint slide
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 26, October 2013, Pages 1–10