Impaction bone grafting using morcellised allograft can successfully restore bone stock in revision surgery. However, concerns exist regarding supply of bone and transmission of infection. Bone-graft extenders, such as tricalcium phosphate (TCP) and hydroxyapatite (HA), are used to minimise the use of donor bone. However, concerns exist around a reported increased risk of femoral fracture during impaction bone grafting with a 1:1 mixture of TCP/HA and morcellised bone graft (MBG) during impaction grafting in human cadaveric femora. Using a sawbones model, it was evaluated whether there was increased femoral cortical strain with a HA:MBG mixture during impaction grafting compared to MBG impacted at the same and a greater force. Subsequently the subsidence behaviour of the different graft mixes was compared by using a loaded femoral stem in an endurance test. It was demonstrated that the femora with the MBG:HA graft had greater cortical hoop stresses but improved subsidence behaviour compared to a graft composed of pure MBG impacted at the same force.
► We examined the effect of impaction force and addition of hydroxyapatite in a hip model.
► Greater force decreases subsidence of a femoral hip stem but increases hoop strain.
► Addition of hydroxyapatite to bone graft decreases femoral implant subsidence.
► Addition of hydroxyapatite to bone graft increases hoop strain during impaction.
► Adding hydroxyapatite to bone graft might be better than increased impaction force.
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 5, Issue 1, January 2012, Pages 238–246