کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8130720 | 1523213 | 2015 | 17 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Complex background suppression for vibro-acoustography images
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
آکوستیک و فرا صوت
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Vibro-acoustography (VA) is an ultrasound-based imaging modality that maps the acoustic response, or acoustic emission, of an object stimulated by two ultrasound waves at slightly different frequencies. VA images typically have a nonzero background intensity which can reduce contrast in images. We present a method that uses the complex representation of the acoustic emission data to estimate and suppress the unwanted background signal. This method utilizes a fast, linear approach to the problem called complex background suppression (CBS) using a square filtering window of size WÂ ÃÂ W. Images processed with the CBS algorithm have significantly enhanced contrast. Another improvement observed with this method is the ability to better localize objects within the depth direction with respect to the ultrasound transducer. This algorithm was tested on images obtained from scanning a phantom with spherical inclusions, a urethane breast phantom, and in vivo human breast. The results show that image quality is improved through processing with the CBS algorithm by increasing the contrast of features in the images. The contrast in the sphere phantom was increased by factors of 2-12 depending on the sphere. Utilizing the CBS algorithm increased the contrast in breast phantom by factors ranging from 1.1 to 5.4 for various inclusions. The size of the filtering window, W, affected the contrast achieved between the phantom features such as the spheres or simulated inclusions and the background material. Application of the CBS algorithm also demonstrated that objects could be localized in depth much better as the relationship to image intensity level was directly correlated to objects located at the center of the focal plane in the axial direction. This method has wide applicability for all VA imaging applications.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasonics - Volume 56, February 2015, Pages 456-472
Journal: Ultrasonics - Volume 56, February 2015, Pages 456-472
نویسندگان
Matthew W. Urban, Chenyi Wang, Azra Alizad, Mostafa Fatemi,