کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8174397 1526352 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Thermal analysis of the first canted-undulator front-end components at SSRF
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Thermal analysis of the first canted-undulator front-end components at SSRF
چکیده انگلیسی
The performance of three kinds of masks: pre-mask, splitter mask and fixed mask-photon shutter, used for the first canted-undulator front end under heat loads at SSRF, is studied. Because these components are shared with two beamlines, the X-rays from both dual undulators and bending magnets can strike on them. Under these complicated conditions, they will absorb much more thermal power than when they operate in usual beamline. So thermal and stress analysis is indispensable for their mechanical design. The method of applying the non-uniform power density using Ansys is presented. During thermal stress analysis, the normal operation or the worst possible case is considered. The finite element analyses results, such as the maximum temperature of the body and the cooling wall and the maximum stress of these components, show the design of them is reasonable and safe.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 774, 21 February 2015, Pages 94-102
نویسندگان
, , , , , ,