Gamma radiation transmission along the multibend mazes
ترجمه فارسی عنوان
انتقال تابش گاما در امتداد چند لنز
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی
Installing a maze on the corridor reduces much shielding materials in shielding door at the end of the pathway. In this study, gamma transmission was measured along single-, double-, and triple-bend mazes, which were applied to nondestructive test workplace by Monte Carlo method. In the facility using 192Ir 1.85 TBq, the lengths of corridors to reduce the effective dose under the limitation without shielding door were 10 and 6 m in double- and triple-bend mazes, respectively.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 114, August 2016, Pages 45-49