کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8651289 | 1572060 | 2018 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Prognostic Impact of Calcium Score after Transcatheter Aortic Valve Implantation Performed With New Generation Prosthesis
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Calcium score (CS) is a well-known prognostic factor after transcatheter aortic valve implantation (TAVI) performed with first generation prosthesis but few data are available concerning new generation valves. The aim of this study was to evaluate if CS remains a prognostic factor after Sapien 3 and Evolut R valves implantation. Agatston CS was evaluated on multislice computed tomography before TAVI in 346 patients implanted with Sapien XT (nâ=â61), CoreValve (nâ=â57) devices, (group 1, nâ=â118), and with new generation Sapien 3 (nâ=â147), Evolut R (nâ=â81) prosthesis, (group 2, nâ=â228). Major adverse cardiovascular events and aortic regurgitation (AR) were evaluated at 1 month. The 2 groups were similar at baseline except for logistic Euroscore (20.1% in group 1 vs 15.0 % in group 2; pâ=â0.001), chronic renal failure (44.1% vs 37.2% respectively, pâ=â0.007) and preprocedural CS (4,092â±â2,176 vs 3,682â±â2,109 respectively, pâ=â0.022). In group 1, 28 patients (23.7%) had adverse clinical events vs 21 (9.2%) in group 2 (pâ<0.01). In multivariate analysis, a higher CS was predictive of adverse events in group 1 (5,785â±â3,285 vs 3,565â±â1,331 pâ<0.0001) but not in group 2 (pâ=â0.28). A higher CS was associated with AR in group 1 (6,234â±â2711 vs 3,429â±â1,505; pâ<0.001) and in patients implanted with an Evolut R device from group 2 (4,085â±â3,645 vs 2,551â±â1,356; pâ=â0.01). In conclusion, CS appears as an important prognostic factor of major events after TAVI with first generation valves but not with new generation devices. CS remains associated with AR only with new generation self-expandable Evolut R devices.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 121, Issue 10, 15 May 2018, Pages 1225-1230
Journal: The American Journal of Cardiology - Volume 121, Issue 10, 15 May 2018, Pages 1225-1230
نویسندگان
Mariama MD, Benoit MD, Audrey MD, Jean-Christophe MD, Thomas MD, Grégory Marin, Anaïs MD, Hélène MD, PhD, Laurent MD, Nicolas MD, PhD, Bernard MD, PhD, Guillaume MD, PhD, Florence MD, PhD,