کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8651619 | 1572071 | 2017 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Anemia and the Risk of Life-threatening Ventricular Tachyarrhythmias from the Israeli Implantable Cardioverter Defibrillator Registry
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Anemia was shown to be associated with increased risk for adverse events in patients with heart failure (HF). However, there are limited data on the association between anemia and the risk for ventricular arrhythmias (VAs) in patients with an implantable cardioverter defibrillator (ICD). The present study population comprised 2,352 patients who were enrolled and prospectively followed up in the Israeli ICD Registry. The risk for a first appropriate ICD shock for VA was assessed by the presence of anemia, categorized at the lower tertile of hemoglobin distribution (â¤12âg/dL [nâ=â753]). Patients who had anemia displayed higher risk clinical characteristics including older age, more advanced HF symptoms, and atrial fibrillation (pâ<0.01 for all). Kaplan-Meier survival analysis showed that at 2.5 years of follow-up the rate of appropriate shocks was significantly higher in patients with low (11%) versus high (6%) hemoglobin (log-rank pâ<0.005). Multivariate analysis showed that anemia was independently associated with a significant 56% increased risk for first appropriate ICD shock (pâ<0.026). When hemoglobin was assessed as a continuous measure, each 1âg/dL reduction in hemoglobin was independently associated with a significant 8% increased risk for first appropriate shock (pâ<0.03). Anemia was also associated with increased risk for all-cause mortality (hazard ratio [HR] 1.78, 95% confidence interval [CI] 1.4 to 2.27], pâ<0.001), HF hospitalizations or death (HR 1.78, 95% CI 1.48 to 1.13, pâ<0.001), but not with inappropriate ICD shocks (HR 1.24, 95% CI 0.70 to 2.21, pâ=â0.47). In conclusion, our findings suggest that the presence of anemia in patients with ICD is associated with increased risk for VA during long-term follow-up.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 120, Issue 12, 15 December 2017, Pages 2187-2192
Journal: The American Journal of Cardiology - Volume 120, Issue 12, 15 December 2017, Pages 2187-2192
نویسندگان
Ido BSc, Alon MD, Avishag MD, Moshe MD, Jorge E. MD, Yoav MD, Michael MD, Mahmoud MD, on behalf of the Israeli Working Group on Pacing and Electrophysiology on behalf of the Israeli Working Group on Pacing and Electrophysiology,