کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8737316 1591330 2018 20 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of Loopamp™MTBC detection kit for diagnosis of pulmonary tuberculosis at a peripheral laboratory in a high burden setting
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
Evaluation of Loopamp™MTBC detection kit for diagnosis of pulmonary tuberculosis at a peripheral laboratory in a high burden setting
چکیده انگلیسی
The Loopamp™MTBC detection kit (TB-LAMP) was designed to replace the sputum smear microscopy for the diagnosis of pulmonary tuberculosis. We evaluated its performance at a peripheral laboratory in Vietnam. The sensitivity of TB-LAMP was 45.5% (28.1%-63.6%), which was equal to 3-sputum smear microscopy but lower than that of Xpert MTB/RIF (87.8% [71.8%-96.6%]). In patients with culture-confirmed TB, sensitivity was 80% (51.9%-95.7%) in smear-positive and 16.7% (3.5%-41.4%) in smear-negative cases. The specificity of TB-LAMP was 95.1% (92.7%-96.9%), which was lower than that of smear microscopy (98.9% [97.5%-99.7%]) and Xpert MTB/RIF (99.3% [98.1%-99.9%]) (P < 0.05). The probability of TB detection by TB-LAMP was more influenced by sample quality and viscosity than were smear microscopy, Xpert MTB/RIF, and culture. The present data do not support the use of TB-LAMP as a replacement test for smear microscopy in peripheral laboratories.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Diagnostic Microbiology and Infectious Disease - Volume 90, Issue 3, March 2018, Pages 190-195
نویسندگان
, , , , , , ,