کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8915453 1641100 2018 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Geoelectrical characterization with 1D VES/TDEM joint inversion in Urupês-SP region, Paraná Basin: Applications to hydrogeology
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فیزیک زمین (ژئو فیزیک)
پیش نمایش صفحه اول مقاله
Geoelectrical characterization with 1D VES/TDEM joint inversion in Urupês-SP region, Paraná Basin: Applications to hydrogeology
چکیده انگلیسی
Although Brazil is well known by the large rivers and the Amazon Rain Forest most cities do not have access to sufficient quantities of surface water to supply the population. Because of this 61% of Brazilian population (IBGE, 2003) depends on groundwater resources. In order to help the conscious exploration of this resource in Urupês city (São Paulo State) which is characterized by problems of lack of water, this research applied the transient electromagnetic method (TDEM) and Vertical Electrical Sounding (VES) for the geoelectrical characterization of the interest region. So, the objective of this work was increase the hydrogeological basis for groundwater exploitation of Bauru sedimentary aquifer and Serra Geral fractured aquifer (Paraná Basin). A total of 23 TDEM and 15 VES soundings were conducted during the years of 2009, 2011 and 2012. In addition, 10 pairs of VES/TDEM soundings were acquired with coincident centers to be able to perform the joint inversion. The joint inversion technique is a promising tool, which enables to get the best of both methods, where the VES add the shallow information and TDEM the deeper one. In this work, the individual and joint inversions were performed using the “Curupira” software. After data process and inversion, the results were interpreted based on geological well information provided by the Department of Water and Electrical Power (DAEE) and the Brazilian Geological Survey (CPRM) which enabled to estimate favorable places to exploitation of water in Bauru and Serra Geral aquifers. For the Bauru aquifer, the results suggest areas where thickness exceeds 100 m. In these areas, the resistivity calculated was about 20 Ω·m. Therefore, the sediments have been interpreted as saturated sandy clay. In the basalt layer of Serra Geral Formation, the suggested locations present resistivity values <100 Ω·m at ~200 m depth. The indicated places in sedimentary aquifer and the locations in the fractured aquifer will may show alternative sources for groundwater exploitation and water supply for Urupês city.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Applied Geophysics - Volume 151, April 2018, Pages 205-220
نویسندگان
, , , , , , , , , ,