کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9034912 1132656 2005 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: First round
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست بهداشت، سم شناسی و جهش زایی
پیش نمایش صفحه اول مقاله
An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: First round
چکیده انگلیسی
The new OECD guideline 429 (skin sensitization: local lymph node assay) is based upon a protocol, which utilises the incorporation of radioactivity into DNA as a measure for cell proliferation in vivo. The guideline also enables the use of alternative endpoints in order to assess draining lymph node (LN) cell proliferation. Here we describe the first round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in seven laboratories. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products, Swissmedic. Statistical analyses of all data were performed by an independent centre at the University of Bern, Department of Statistics. Ear-draining, LN weight and cell count were used to assess proliferation instead of radioactive labeling of lymph node cells. In addition, the acute inflammatory skin reaction was measured by ear swelling and weight of circular biopsies of the ears to identify skin irritating properties of the test items. Hexylcinnamaldehyde (HCA) and three blinded test items were applied to female, 8-10 weeks old NMRI and BALB/c mice. Results were sent via the independent study coordinator to the statistician. The results of this first round showed that the alternative endpoints of the LLNA are sensitive and robust parameters. The use of ear weights added an important parameter assessing the skin irritation potential, which supports the differentiation of pure irritative from contact allergenic potential. There were absolute no discrepancies between the categorisation of the three test substances A-C determined by each single participating laboratories. The results highlighted also that many parameters do have an impact on the strength of the responses. Therefore, such parameters have to be taken into consideration for the categorisation of compounds due to their relative sensitizing potencies.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Toxicology - Volume 212, Issue 1, 15 August 2005, Pages 60-68
نویسندگان
, , , , , , , , , , , ,