کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
917151 1473418 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of fetal and maternal heart rate measures using electrocardiographic and cardiotocographic methods
ترجمه فارسی عنوان
مقایسه مقادیر ضربان قلب جنین و مادر با استفاده از روشهای الکتروکاردیوگرافی و قلب شناسی
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب رفتاری
چکیده انگلیسی


• Reliability of cardiotocograph with electrocardiograph measures of fetal heart rate during maternal rest and fetal auditory stimulation was demonstrated.
• There was high reliability when heart rate was aggregated over fetuses and/or 30 s–20 min epochs.
• Measures of maternal heart rate showed high reliability between a maternal–fetal ECG and stand-alone ECG devices.

PurposeTo determine the reliability at term of: (1) two methods of measuring fetal heart rate (HR), electrocardiographic (ECG, the ‘gold standard’) and cardiotocographic (CTG) and (2) two ECG methods of measuring maternal HR variability over relatively brief periods of time (s–min).MethodsDuring 20 min of rest (N = 39) and during 2 min of auditory stimulation (mother's recorded voice, n = 19), fetal HR data were collected using an ECG (Monica AN24) and a Hewlett-Packard Model 1351A CTG. Simultaneously, maternal HR data (n = 37) were collected using the same ECG device (Monica AN24) and a second stand-alone cardiac monitor (Spacelab 514T cardiac monitor with a QRS detector).ResultsDuring 20 min of maternal rest, correlations of individual fetal CTG with ECG measures of HR at each second were moderate to high (r = .57–.97) for 77% of fetuses. Correlations of HR averaged over fetuses and over each of the 20 min were high (r = .93–.97); fetal HR averaged over 20 min varied between devices from 0.0 to 0.8 bpm. During 2 min of maternal voice presentation, correlations of fetal HR over each second were moderate to high (r = .54–.99) for 95% of fetuses and high (all rs = .99) when averaged across fetuses in 30 s or 2 min epochs. Average fetal HR between devices over the 2 min voice varied from 0.0 to 0.6 bpm. Correlations and/or % agreement between the two ECG methods of measuring maternal HR were high. Average maternal HR over 10 min showed 81% of pairs with a difference of ≤1 bpm; correlations for HR variability measures varied from r = .89 to .97.ConclusionsGood reliability was demonstrated between individual spontaneous and auditory induced fetal CTG and ECG with high correlations when HR data were averaged over fetuses or in 30–120 s epochs. High reliability of maternal HR measures was obtained using two ECG devices.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Infant Behavior and Development - Volume 42, February 2016, Pages 142–151
نویسندگان
, ,