کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9629160 461287 2005 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigations on fouling rate in convective bundles of coal-fired boilers in relation to optimization of sootblower operation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Investigations on fouling rate in convective bundles of coal-fired boilers in relation to optimization of sootblower operation
چکیده انگلیسی
The article deals with results of full-scale investigations on fouling in convective bundles of chosen types of coal-fired boilers. The boilers tested were: conventional pulverized-coal fired two-pass boilers (two types), a single-pass subcritical (a tower shape) boiler and CFB boiler. Mechanisms of deposit formation and basics of deposit modeling are shortly discussed. An own approach to predict build-up of loose powdery sediments was developed on the basis of the results of full-scale measurements. The correlation for maximum fouling time was obtained by statistical processing of measurement data and is applied in optimization of sootblower system operation. The obtained correlation depends on the following variables: geometric properties of the bundle, fly ash size distribution and basic parameters of the flue gases-all of them are easily accessible in boiler operation.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fuel - Volume 84, Issues 7–8, May 2005, Pages 927-937