کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9638197 505049 2005 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Power dissipation and energy transfer during testing of the ITER toroidal field model coil
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Power dissipation and energy transfer during testing of the ITER toroidal field model coil
چکیده انگلیسی
The testing of the ITER toroidal field model coil (TFMC) in the background field of the EURATOM-LCT coil took place in autumn 2002 at the TOSKA facility of the Forschungszentrum Karlsruhe in the framework of the ITER R&D programme. The maximum currents in the two coils, in combined operation, were 16 kA in the LCT coil and 80 kA in the TFMC, respectively. The heat load of both coils, including the eddy current losses in the passive structures and the joule losses due to the joint resistances, was removed by a secondary loop of forced flow supercritical He. About 2% of the stored energy was transferred to the cryogenic system after all the safety discharges of both coils together. Most of the energy (about 98%) was extracted and transferred to the dump resistors of both coils, located outside the vacuum vessel. A computer code, based on the full inductance and resistance matrices, has been developed with SIMULINK™. After validation with experimental data the code has been used to perform circuit analysis and to evaluate the power dissipation and energy transferred to the cryogenic plant and to the external power circuits.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volumes 75–79, November 2005, Pages 17-21