Thermal analysis and Ohmic loss estimation of polarizer for ITER ECCD system
چکیده انگلیسی
A high power polarizer using a single grooved mirror has been developed for an electron cyclotron current drive (ECCD) system of the International Thermonuclear Experimental Reactor (ITER). Two grooved mirrors were tested at a frequency of 170 GHz, rf power of 441 kW and a pulse duration of 0.1-6 s for estimating Ohmic losses. The Ohmic loss of grooved mirror strongly depends not only on the rotation angle of the polarization plane of the incident waves, but also on the mirror rotaion angle. The thermal analysis of the grooved mirror has been performed with the 3D FEM code: FEVA.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 74, Issues 1–4, November 2005, Pages 473-478