Consolidation of scientific and technological expertise to assess the reliability of reactor pressure vessel embrittlement prediction in particular for the arctic area plant (COBRA)
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The COBRA project, which started in August 2000 and had a duration of 3 years, was designed to solve the above-mentioned problems. Surveillance capsules were manufactured which contained state of art dosimeters and temperature monitors (melting alloys). In addition, thermocouples were installed throughout the instrumentation channels of the vessel head to measure directly the irradiation temperature in the surveillance position during reactor operation. The selected reactor for the experiment was the Unit 3 of Kola NPP situated in the arctic area of Russia. Irradiation of capsules and online temperature measurements were performed during one fuel cycle. On the base of statistical processing of thermocouples readings, the temperature of irradiated surveillance specimens in WWER-440/213 reactor can be accepted as 269.5 ± 4 °C. Uncertainties were evaluated also with experimental work carried out in the WWRSZ research reactor and by finite element modelling of surveillance capsules. The results obtained show that there is not need to perform temperature correction when surveillance data of irradiated specimens are used for embrittlement assessment of WWER-440(213) reactor pressure vessels. Maximum neutron flux evaluated using detectors, which were placed in the Charpy specimen simulators, equals â¼2.7 Ã 1012 cmâ2 sâ1 with E > 0.5 MeV. It is established that depending on the orientation of the capsules with respect to the core, the detectors of the standard surveillance capsules can give both overestimated and underestimated neutron flux values, as compared to the actual flux received by the surveillance specimens. The overestimation or underestimation can reach 10%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 235, Issues 2â4, February 2005, Pages 411-419
Journal: Nuclear Engineering and Design - Volume 235, Issues 2â4, February 2005, Pages 411-419
نویسندگان
A. Ballesteros, J. Bros, L. Debarberis, F. Sevini, D. Erak, S. Gezashchenko, A. Kryukov, Y. Shtrombakh, S. Goloschapov, Ionov Ionov, Y. Pytkin, Y. Anikeev, G. Banyuk, A. Plusch, F. Gillemot, L. Tatar, V. Petrosyan,