کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9684965 1456219 2005 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preparation of an acetylene black-dihexadecyl hydrogen phosphate composite film modified glassy carbon electrode and the application in the determination of hydroxycamptothecin in blood serum
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Preparation of an acetylene black-dihexadecyl hydrogen phosphate composite film modified glassy carbon electrode and the application in the determination of hydroxycamptothecin in blood serum
چکیده انگلیسی
A novel method for the fabrication of acetylene black-dihexadecyl hydrogen phosphate (AB-DHP) composite film modified glassy carbon electrodes (GCEs) was presented, and based on this, a sensitive electrochemical method for the determination of hydroxycamptothecin (HCPT) was developed. Compared with the poor signal at GCE, the electrochemical response of HCPT at AB-DHP composite film modified GCE was greatly improved, which was confirmed by the significant enhancement of the oxidation current. After the optimization of experimental parameters, the dependence of oxidation current on HCPT concentration was explored, which exhibited a good linear relationship in the range of 1.0 × 10−9 to 1.5 × 10−6 mol l−1. The detection limit of HCPT was also examined and a low value of 5.0 × 10−10 mol l−1 for 6 min accumulation was obtained (S/N = 3). This electrode was successfully applied to the detection of HCPT in cancer patient's serum samples.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Membrane Science - Volume 251, Issues 1–2, 1 April 2005, Pages 43-49
نویسندگان
,