Relative biologic effectiveness determination in mouse intestine for scanning proton beam at Paul Scherrer Institute, Switzerland. Influence of motion
چکیده انگلیسی
Conclusion: The results of this study have shown that the RBE of the PSI proton beam is in total accordance with the RBE obtained at the other centers. This experiment has corroborated that proton RBE at the middle of the SOBP is slightly larger than the generic value of 1.10 and that there is a slight tendency for the RBE to increase close to the end of the SOBP. Also, excessive dispersion of individual proton data may be considered to result from intestine motion, taking into account that irradiation at the PSI is delivered dynamically by scanning the target volume with a pencil proton beam (“spot scanning”). Because 2-mm movements resulted in significant variations in local dose depositions, this should be considered for moving targets. Strategies to reduce this effect for the spot scanning technique have been developed at the PSI for radiotherapy of humans.