Enhanced delivery of iodine for synchrotron stereotactic radiotherapy by means of intracarotid injection and blood-brain barrier disruption: Quantitative iodine biodistribution studies and associated dosimetry
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Enhanced delivery of iodine for synchrotron stereotactic radiotherapy by means of intracarotid injection and blood-brain barrier disruption: Quantitative iodine biodistribution studies and associated dosimetry
چکیده انگلیسی
This study established that optimizing the delivery of iodine by means of IC injection combined with a blood-brain barrier opener (mannitol) significantly increases the iodine uptake of F98 rat gliomas. This infusion protocol could potentially enhance the efficacy of SSR treatment, because the radiation dose is proportional to the iodine amount present in the irradiation bed.