کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
9936653 | 1572459 | 2005 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Comparison of low-mechanical index pulse sequence schemes for detecting myocardial perfusion abnormalities during vasodilator stress echocardiography
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Myocardial contrast echocardiography has the potential to accurately detect functionally significant coronary artery disease during pharmacologic stress testing. Different low-mechanical index modalities, including triggering replenishment imaging (TRI) and real-time imaging (RTI), are currently used to identify myocardial perfusion defects. We compared the ability of TRI with that of RTI for detecting and localizing perfusion abnormalities. Thirty-six patients (62 ± 14 years old, 15 men) underwent single-photon emission computed tomography (SPECT) with technetium-99m sestamibi and myocardial contrast echocardiography at baseline and after infusion of 0.56 mg/kg of dipyridamole. Sixteen of these patients also underwent quantitative angiography. Contrast-enhanced images were obtained in 4-, 3-, and 2-chamber views after intravenous bolus injections of lipid-encapsulated microbubbles (0.1 ml of Definity). A myocardial perfusion defect was defined by myocardial contrast echocardiography as a delay of >2 seconds in contrast replenishment after high-mechanical index flash impulse. The myocardial segments were divided into 3 major coronary territories. There was agreement in detecting perfusion defects between SPECT and TRI in 26 patients (72%, κ = 0.46) and between SPECT and RTI in 27 patients (75%, κ = 0.50). Agreements between myocardial contrast echocardiography and SPECT for localizing coronary territories with perfusion defects were 81% for TRI (κ = 0.43) and 85% for RTI (κ = 0.61). Accuracy of RTI for detecting >50% diameter stenoses by quantitative angiography was 79%, that of TRI was 71%, and that of SPECT was 65%. These data indicate that the different low-mechanical index imaging schemes are equivalent to radionuclide SPECT in accurately detecting diseased coronary artery territories during vasodilator stress.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The American Journal of Cardiology - Volume 95, Issue 5, 1 March 2005, Pages 565-570
Journal: The American Journal of Cardiology - Volume 95, Issue 5, 1 March 2005, Pages 565-570
نویسندگان
Jeane M. MD, Feng MD, Anna C. RN, BSN, Heidi RDCS, Jordan MD, Edward L. MD, Thomas R. MD,