کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10136952 1645696 2018 17 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Micro-dosimetry calculation of Auger-electron-emitting radionuclides mostly used in nuclear medicine using GEANT4-DNA
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Micro-dosimetry calculation of Auger-electron-emitting radionuclides mostly used in nuclear medicine using GEANT4-DNA
چکیده انگلیسی
S-values of some of the diagnostic radioisotopes, including 123I, 125I, 99mTc, 67Ga, 201Tl, and 111In, were evaluated in a homogeneous spherical geometry model with unit density in which the cell and nucleus were concentric. The results revealed that S-values of these diagnostic radioisotopes were mainly greater than S-values of the radioisotope 131I, which emits β-particles; they were lower but can be compared with 211At (emitter of alpha particles) in the cellular scale. It shows better the importance of dosimetry calculation of diagnostic Auger-electron-emitting radioisotope in a cellular scale and their applicability in treatment. It should be noted that the S-values obtained out of the Geant4-DNA simulation are in line with the values of the other codes and the MIRD technique.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 141, November 2018, Pages 73-79
نویسندگان
, ,