Development of photocatalytic biosensor for the evaluation of biochemical oxygen demand
چکیده انگلیسی
The photocatalytic biosensor of flow system using semiconductor TiO2 was developed to evaluate biochemical oxygen demand (BOD) levels in river water. Photocatalysis of sample was carried out in a photoreactor with TiO2 and a 6 W black-light blue fluorescent tube as light source. Sample from a photoreactor outlet was measured by an oxygen electrode with a biofilm. The sensor response of photocatalytic biosensor was between 5 and 10 min depending on concentration of biochemical in the samples. At BOD of 1 mg l−1, the sensor response increased 1.33-fold in comparison with that without photocatalysis. The degradation of tannic acid and humic acid with photocatalysis were 51.8 and 38.4%, respectively. Gum arabic and linear alkylbenzene sulfonate (LAS) were degraded a little, but gave the responses of more than double to the sensor. Free radicals yielded by photocatalysis in a photoreactor did not affect the sensor response because their lifetime is extremely short. Fairly good correlation (r = 0.983) between the sensor method and the conventional method was obtained for test samples. This biosensor using photocatalytic pretreatment improved the sensitivity.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 21, Issue 1, 15 July 2005, Pages 67-73