کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1211884 1494036 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination and characterization of total thiols in mouse serum samples using hydrophilic interaction liquid chromatography with fluorescence detection and mass spectrometry
ترجمه فارسی عنوان
تعیین و مشخص نمودن تیول های کل در نمونه های سرم موش ها با استفاده از کروماتوگرافی مایع متقاطع هیدرولیک با تشخیص فلورسانس و طیف سنجی جرمی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• An HILIC-fluorescence detection method for biothiols was developed.
• Seven thiols were separated within 16 min using an amide HILIC column.
• Five thiols related to glutathione in mouse serum samples were quantified.
• Two unknown compounds having thiol groups were found in mouse serum samples.
• The exact masses of the two unknown compounds were determined by HILIC–HRMS.

Biothiols such as homocysteine, cysteine, and glutathione play many biologically important roles, especially in reduction–oxidation homeostasis and resistance to oxidative stress, and the measurement of their concentrations in model animal fluids is important in clarifying the pathology of thiol-related diseases. In this study, an analytical method for total biothiols in mouse serum using hydrophilic interaction liquid chromatography (HILIC) with fluorescence detection was developed. Mouse serum samples were derivatized with ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F), after reduction by tris(2-carboxyethyl)phosphine. Five biothiols (homocysteine, cysteine, cysteinylglycine, glutathione, and γ-glutamylcysteine) in the mouse sera were separated within 16 min on an amide-type HILIC column. The method possessed good linearity, good reproducibility with an intra-day variance of less than 3%, and low detection limits of 0.2–4 nM. Concentrations of homocysteine, cysteine, cysteinylglycine, glutathione, and γ-glutamylcysteine in the mouse serum samples were calculated as 6.7 ± 0.3, 227.7 ± 16.9, 1.2 ± 0.4, 77.5 ± 29.2, and 8.2 ± 0.9 μM, respectively (mean ± S.D., n = 4). Furthermore, HILIC-negative electrospray ionization–mass spectrometry (MS) analysis using a high-resolution mass spectrometer was conducted to determine the exact masses of two unknown peaks, which were found in the mouse serum samples with high signal intensity and were not detected in human plasma samples. The exact masses of the unknown compounds were determined as 1184.519 and 800.281 (as SBD-derivatized negative ions), which possessed a product ion common to SBD-thiols (m/z 230.954, as [SBD-SH]−) upon tandem MS spectrometric analysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 1019, 15 April 2016, Pages 59–65
نویسندگان
, , , ,